Manual Fixed ACB with Three Pole having Microprocessor based Release IPR 2

Ranging from 630 A - 4000 A having Icu = 50 kA & 65 kA for 630 A - 2000 A; Icu = 75 kA for 2500 A & Icu = 100 kA for 3200 A - 4000 A

Range 630 A - 4000 A, Breaking Capacity 50 kA - 100 kA in TP & FP

Different Current Rating provide selection option depending on varied Load Conditions

Mid Version

Circuit Breaker offers all basic protections along with LCD Display and Fault History

Measurement Function Available

Facility of Current, Voltage and Energy measurement available

MRP Rs.: ₹ ..000

Buy Now
Function Check Facility Available

Function Check Facility Available

It allows to individually check the performance of respective functions of the release

Pre Indication of Fault condition

Pre Indication of Fault condition

Advance Indication of Fault condition available with the help of Pre Trip Alarm facility

Offers Self Monitoring

Offers Self Monitoring

Independently the release can be tested for all the functions

Provision of Operation Counter

Provision of Operation Counter

It records the number of ON / OFF operation of the circuit breaker

Fault History Facility Available

Fault History Facility Available

It records and displays last 100 faults hence enables planning of maintenance schedule

Password protected

Password protected

The release is Password protected thereby restricting the access of unauthorised person

Current & Time Setting Available

Current & Time Setting Available

Setting of Current & Time Delay is totally error free & is user friendly

Close and Precise protection

Close and Precise protection

It is Equipped with 16 bit micro controller, these are far more reliable and have high level of repeat accuracy when compared to thermal magnetic and static releases

Monitors & Measures Actual Current

Monitors & Measures Actual Current

It offers True RMS sensing with total immunity to system disturbances

No external Power Required

No external Power Required

It is Self-Powered by built in current transformer

Technical Specification

basic features
ref standard IS / IEC 60947-2
rated operational voltage 690/250 V AC
rated insulation voltage 1000 V AC
rated impulse voltage 12 kV
utilisation category B
rated frequency 50/60 Hz
operating altitude 2000 m
humidity 0 - 90%
rating range 630 A - 4000 A
no. of poles Three
breaking capacity withstand capacity Icu = Ics = Icw = 50 kA & 65 kA for 630 A - 2000 A; Icu = Ics = Icw = 75 kA for 2500 A; Icu = Ics = Icw = 100 kA for 3200 A - 4000 A
version Fixed Type
type of operation Manual

Demo Videos