Havells - Thermal Magnetic Adjustable MCCB with 3 Pole from 250 A - 630 A, 36 kA

With Adjustable both Thermal & Magnetic Settings having 36 kA Breaking Capacity with Ics = 100% of Icu    IHLLSECT0250

  • Range 250 A - 630 A, Icu/Ics- 36/36 kA & 50/37.5 kA
  • Versions - 3P & 4Pwsn
  • Adjustable Thermal & Fixed/Adjustable Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic Adjustable MCCB with 3 Pole from 160 A - 800 A, 50 kA

With Adjustable both Thermal & Magnetic Settings having 50 kA Breaking Capacity with Ics = 50% of Icu    IHLCHT0160

  • Range 160 A - 800 A, Icu/Ics-35/25 kA & 50/25 kA
  • Versions - 2P, 3P & 4Pwsn
  • Adjustable Thermal & Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic Adjustable MCCB with 3 Pole from 160 A - 800 A, 35 kA

With Adjustable both Thermal & Magnetic Settings having 35 kA Breaking Capacity with Ics = 75% of Icu    IHLCNT0160

  • Range 160 A - 800 A, Icu/Ics-35/25 kA & 50/25 kA
  • Versions - 2P, 3P & 4Pwsn
  • Adjustable Thermal & Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic Adjustable MCCB with 3 Pole from 160 A - 250 A, 25 kA

With Adjustable both Thermal & Magnetic Settings having 25 kA Breaking Capacity with Ics = 75% of Icu    IHLANDCT0160

  • Range 25 A - 250 A, Icu/Ics- 16/16 kA, 25/18.75 kA & 35/25 kA
  • Version - 1P, 3P & 4Pwsn
  • Adjustable Thermal & Fixed Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic Adjustable MCCB with 3 Pole from 1000 A - 1600 A, 50 kA

With Adjustable both Thermal & Magnetic Settings having 16 kA Breaking Capacity with Ics = 100% of Icu    IHLASBCT0160

  • Range 25 A-250 A, Icu/Ics- 16/16 kA, 25/18.75 kA & 35/25 kA
  • Version - 1P, 3P & 4Pwsn
  • Adjustable Thermal & Fixed Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic Adjustable MCCB with 3 Pole from 1000 A - 1600 A, 50 kA

With Adjustable both Thermal & Magnetic Settings having 50 kA Breaking Capacity with Ics = 75% of Icu    IHLDNT1000

  • Range 1000 A - 1600 A, Icu/Ics-50/37.5 kA
  • Versions - 3P
  • Adjustable Thermal & Magnetic Settings with Pole wise Adjustability Feature

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic Adjustable MCCB with 3 Pole from 250 A - 630 A, 50 kA

With Adjustable both Thermal & Magnetic Settings having 50 kA Breaking Capacity with Ics = 75% of Icu    IHLLNFCT0250

  • Range 250A-630A,Icu/Ics- 36/36kA & 50/37.5kA
  • Versions - 3P & 4Pwsn
  • Adjustable Thermal & Fixed/Adjustable Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic Adjustable MCCB with 3 Pole from 80 A - 125 A, 25 kA

With Adjustable both Thermal & Magnetic Settings having 25 kA Breaking Capacity with Ics = 75% of Icu    IHLASDCT0080

  • Range 25 A - 250 A, Icu/Ics- 16/16 kA, 25/18.75 kA & 35/25 kA
  • Version - 1P, 3P & 4Pwsn
  • Adjustable Thermal & Fixed Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic Adjustable MCCB with 3 Pole from 80 A - 125 A, 35 kA

With Adjustable both Thermal & Magnetic Settings having 35 kA Breaking Capacity with Ics = 75% of Icu    IHLANECT0080

  • Range 25 A - 250 A, Icu/Ics- 16/16 kA, 25/18.75 kA & 35/25 kA
  • Version - 1P, 3P & 4Pwsn
  • Adjustable Thermal & Fixed Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic Adjustable MCCB with 4 Pole from 160 A - 200 A, 16 kA

With Adjustable both Thermal & Magnetic Settings having 16 kA Breaking Capacity with Ics = 100% of Icu    IHLASBCF0160

  • Range 25 A - 250 A, Icu/Ics- 16/16 kA, 25/18.75 kA & 35/25 kA
  • Version - 1P, 3P & 4Pwsn
  • Adjustable Thermal & Fixed Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic Adjustable MCCB with 4 Pole from 160 A - 250 A, 25 kA

With Adjustable both Thermal & Magnetic Settings having 25 kA Breaking Capacity with Ics = 75% of Icu    IHLANDCF0160

  • Range 25 A - 250 A, Icu/Ics- 16/16 kA, 25/18.75 kA & 35/25 kA
  • Version - 1P, 3P & 4Pwsn
  • Adjustable Thermal & Fixed Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic Adjustable MCCB with 4 Pole from 160 A - 800 A, 35 kA

With Adjustable both Thermal & Magnetic Settings having 35 kA Breaking Capacity with Ics = 75% of Icu    IHLCNF0160

  • Range 160 A - 800 A, Icu/Ics-35/25 kA & 50/25 kA
  • Versions - 2P, 3P & 4Pwsn
  • Adjustable Thermal & Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic Adjustable MCCB with 4 Pole from 160 A - 800 A, 50 kA

With Adjustable both Thermal & Magnetic Settings having 50 kA Breaking Capacity with Ics = 50% of Icu    IHLCHF0160

  • Range 160 A - 800 A, Icu/Ics-35/25 kA & 50/25 kA
  • Versions - 2P, 3P & 4Pwsn
  • Adjustable Thermal & Magnetic Settings

MRP Rs.: ₹ 0

Download
Havells
Havells - Thermal Magnetic Adjustable MCCB with 4 Pole from 250 A - 630 A, 36 kA

With Adjustable both Thermal & Magnetic Settings having 36 kA Breaking Capacity with Ics = 100% of Icu    IHLLSECF0250

  • Range 250 A - 630 A, Icu/Ics- 36/36 kA & 50/37.5 kA
  • Versions - 3P & 4Pwsn
  • Adjustable Thermal & Fixed/Adjustable Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic Adjustable MCCB with 4 Pole from 250 A - 630 A, 50 kA

With Adjustable both Thermal & Magnetic Settings having 50 kA Breaking Capacity with Ics = 75% of Icu    IHLLNFCF0250

  • Range 250 A -630 A, Icu/Ics- 36/36 kA & 50/37.5 kA
  • Versions - 3P & 4Pwsn
  • Adjustable Thermal & Fixed/Adjustable Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic Adjustable MCCB with 4 Pole from 80 A - 125 A, 25 kA

With Adjustable both Thermal & Magnetic Settings having 25 kA Breaking Capacity with Ics = 75% of Icu    IHLASDCF0080

  • Range 25 A - 250 A , Icu/Ics- 16/16 kA, 25/18.75 kA & 35/25 kA
  • Version - 1P, 3P & 4Pwsn
  • Adjustable Thermal & Fixed Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic Adjustable MCCB with 4 Pole from 80 A - 125 A, 35 kA

With Adjustable both Thermal & Magnetic Settings having 35 kA Breaking Capacity with Ics = 75% of Icu    IHLANECF0080

  • Range 25 A - 250 A, Icu/Ics- 16/16 kA, 25/18.75 kA & 35/25 kA
  • Version - 1P, 3P & 4Pwsn
  • Adjustable Thermal & Fixed Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 4 Pole from 40 A - 160 A, 27 kA

With Adjustable Thermal & Fixed Magnetic Settings having 27 kA Breaking Capacity with Ics = 100% of Icu    IHENSDBF0040

  • Range 40 A - 160 A, Icu/Ics- 27/27 kA & 36/36 kA
  • Version - 1P, 2P, 3P & 4P
  • Adjustable Thermal & Fixed Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 4 Pole from 40 A - 160 A, 27 kA

With Adjustable Thermal & Fixed Magnetic Settings having 36 kA Breaking Capacity with Ics = 100% of Icu    IHENHEBF0040

  • Range 40 A - 160 A, Icu/Ics- 27/27 kA & 36/36 kA
  • Version - 1P, 2P, 3P & 4P
  • Adjustable Thermal & Fixed Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 1 Pole from 160 A - 250 A, 25 kA

With Adjustable Thermal & Fixed Magnetic Settings having 25 kA Breaking Capacity with Ics = 75% of Icu    IHLANS0160

  • Range 25 A - 250 A, Icu/Ics- 16/16 kA, 25/18.75 kA & 35/25 kA
  • Version - 1P, 3P & 4Pwsn
  • Adjustable Thermal & Fixed Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 1 Pole from 25 A - 125 A, 25 kA

With Adjustable Thermal & Fixed Magnetic Settings having 25 kA Breaking Capacity with Ics = 75% of Icu    IHLASS0025

  • Range 25 A - 250 A, Icu/Ics- 16/16 kA, 25/18.75 kA & 35/25 kA
  • Version - 1P, 3P & 4Pwsn
  • Adjustable Thermal & Fixed Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 1 Pole from 160 A - 250 A, 25 kA

With Fixed Thermal/Magnetic Settings having 10 kA Breaking Capacity with Ics = 100% of Icu    IHLGSS0025

  • Range 15A-100A,Icu/Ics- 10/10kA,18/18kA & 25/18.75kA
  • Versions - 1P, 3P & 4Pwsn
  • Fixed Thermal & Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 1 Pole from 25 A - 160 A, 18 kA

With Fixed Thermal/Magnetic Settings having 18 kA Breaking Capacity with Ics = 100% of Icu    IHLGNS0025

  • Range 15 A - 100 A, Icu/Ics- 10/10 kA,18/18 kA & 25/18.75 kA
  • Versions - 1P, 3P & 4Pwsn
  • Fixed Thermal & Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 1 Pole from 25 A - 160 A, 25 kA

With Fixed Thermal/Magnetic Settings having 25 kA Breaking Capacity with Ics = 75% of Icu    IHLGHDAS0025

  • Range 15 A - 100 A, Icu/Ics- 10/10 kA, 18/18 kA & 25/18.75 kA
  • Versions - 1P, 3P & 4Pwsn
  • Fixed Thermal & Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 1 Pole from 40 A - 160 A, 27 kA

With Adjustable Thermal & Fixed Magnetic Settings having 27 kA Breaking Capacity with Ics = 100% of Icu    IHLNSDBS0040

  • Range 40 A - 160 A, Icu/Ics- 27/27 kA & 36/36 kA
  • Version - 1P, 2P, 3P & 4P
  • Adjustable Thermal & Fixed Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 1 Pole from 40 A - 160 A, 36 kA

With Adjustable Thermal & Fixed Magnetic Settings having 36 kA Breaking Capacity with Ics = 100% of Icu    IHLNHEBS0040

  • Range 40 A - 160 A, Icu/Ics - 27/27 kA & 36/36 kA
  • Version - 1P, 2P, 3P & 4P
  • Adjustable Thermal & Fixed Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 2 Pole from 40 A - 160 A, 27 kA

With Adjustable Thermal & Fixed Magnetic Settings having 27 kA Breaking Capacity with Ics = 100% of Icu    IHLNSDBD0040

  • Range 40 A-160 A, Icu/Ics- 27/27 kA & 36/36 kA
  • Version - 1P, 2P, 3P & 4P
  • Adjustable Thermal & Fixed Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 2 Pole from 40 A - 160 A, 36 kA

With Adjustable Thermal & Fixed Magnetic Settings having 36 kA Breaking Capacity with Ics = 100% of Icu    IHLNHEBD0040

  • Range 40 A-160 A, Icu/Ics- 27/27 kA & 36/36 kA
  • Version - 1P, 2P, 3P & 4P
  • Adjustable Thermal & Fixed Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 2 Pole from 15 A - 100 A

With Fixed Thermal/Magnetic Settings having 10 kA Breaking capacity with Ics = 50% of Icu    IHLSHAAD0015

  • Range 15 A - 100 A, Icu/Ics- 10/5 kA
  • Versions - 2P, 3P & 4Pwsn
  • Fixed Thermal & Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 3 Pole from 160 A - 200 A, 16 kA

With Adjustable Thermal & Fixed Magnetic Settings having 16 kA Breaking Capacity with Ics = 100% of Icu    IHLAST0160

  • Range 25 A - 250 A, Icu/Ics- 16/16 kA, 25/18.75 kA & 35/25 kA
  • Version - 1P, 3P & 4Pwsn
  • Adjustable Thermal & Fixed Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 3 Pole from 160 A - 250 A, 25 kA

With Adjustable Thermal & Fixed Magnetic Settings having 25 kA Breaking Capacity with Ics = 75% of Icu    IHLANT0160

  • Range 25 A - 250 A, Icu/Ics- 16/16 kA, 25/18.75 kA & 35/25 kA
  • Version - 1P, 3P & 4Pwsn
  • Adjustable Thermal & Fixed Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 3 Pole from 250 A - 630 A, 36 kA

With Adjustable Thermal & Fixed Magnetic Settings having 36kA Breaking Capacity with Ics = 100% of Icu    IHLLSEBT0250

  • Range 250 A - 630 A, Icu/Ics- 36/36 kA & 50/37.5 kA
  • Versions - 3P & 4Pwsn
  • Adjustable Thermal & Fixed/Adjustable Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 3 Pole from 250 A - 630 A, 50 kA

With Adjustable Thermal & Fixed Magnetic Settings having 50 kA Breaking Capacity with Ics = 75% of Icu    IHLLNFBT0250

  • Range 250 A - 630 A, Icu/Ics- 36/36 kA & 50/37.5 kA
  • Versions - 3P & 4Pwsn
  • Adjustable Thermal & Fixed/Adjustable Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 3 Pole from 25 A - 125 A, 25 kA

With Adjustable Thermal & Fixed Magnetic Settings having 25 kA Breaking Capacity with Ics = 75% of Icu    IHLAST0025

  • Range 25 A - 250 A, Icu/Ics- 16/16 kA, 25/18.75 kA & 35/25 kA
  • Version - 1P, 3P & 4Pwsn
  • Adjustable Thermal & Fixed Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 3 Pole from 25 A - 125 A 35 kA

With Adjustable Thermal & Fixed Magnetic Settings having 35 kA Breaking Capacity with Ics = 75% of Icu    IHLANT0025

  • Range 25 A - 250 A, Icu/Ics- 16/16 kA, 25/18.75 kA & 35/25 kA
  • Version - 1P, 3P & 4Pwsn
  • Adjustable Thermal & Fixed Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 3 Pole from 25 A - 160 A, 10 kA

With Fixed Thermal/Magnetic Settings having 10 kA Breaking Capacity with Ics = 100% of Icu    IHLGST0025

  • Range 15 A - 100 A, Icu/Ics- 10/10 kA, 18/18 kA & 25/18.75 kA
  • Versions - 1P, 3P & 4Pwsn
  • Fixed Thermal & Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 3 Pole from 25 A - 160 A, 18 kA

With Fixed Thermal/Magnetic Settings having 18 kA Breaking Capacity with Ics = 100% of Icu    IHLGNT0025

  • Range 15 A - 100 A, Icu/Ics- 10/10 kA, 18/18 kA & 25/18.75 kA
  • Versions - 1P, 3P & 4Pwsn
  • Fixed Thermal & Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 3 Pole from 25 A - 160 A, 25 kA

With Fixed Thermal/Magnetic Settings having 25 kA Breaking Capacity with Ics = 75% of Icu    IHLGHT0025

  • Range 15 A - 100 A, Icu/Ics- 10/10 kA, 18/18 kA & 25/18.75 kA
  • Versions - 1P, 3P & 4Pwsn
  • Fixed Thermal & Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 3 Pole from 25 A - 250 A, 35 kA

With Fixed Thermal/Magnetic Settings having 35 kA Breaking Capacity with Ics = 100% of Icu    IHLFNT0025

  • Range 25 A - 250 A, Icu/Ics- 35/35 kA & 50/50 kA
  • Versions - 1P, 3P & 4Pwsn
  • Fixed Thermal & Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 3 Pole from 25 A - 250 A, 50 kA

With Fixed Thermal/Magnetic Settings having 50 kA Breaking Capacity with Ics = 100% of Icu    IHLFHT0025

  • Range 25 A - 250 A, Icu/Ics- 35/35 kA & 50/50 kA
  • Versions - 1P, 3P & 4Pwsn
  • Fixed Thermal & Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 3 Pole from 40 A - 160 A, 27 kA

With Adjustable Thermal & Fixed Magnetic Settings having 27 kA Breaking Capacity with Ics = 100% of Icu    IHLNSDBT0040

  • Range 40 A - 160 A, Icu/Ics- 27/27 kA & 36/36 kA
  • Version - 1P, 2P, 3P & 4P
  • Adjustable Thermal & Fixed Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 3 Pole from 40 A - 160 A, 36 kA

With Adjustable Thermal & Fixed Magnetic Settings having 36 kA Breaking Capacity with Ics = 100% of Icu    IHLNHEBT0040

  • Range 40 A - 160 A, Icu/Ics- 27/27 kA & 36/36 kA
  • Version - 1P, 2P, 3P & 4P
  • Adjustable Thermal & Fixed Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 3 Pole from 15 A - 100 A

With Fixed Thermal/Magnetic Settings having 10 kA Breaking capacity with Ics = 50% of Icu    IHLSHAAT0015

  • Range 15 A-100 A, Icu/Ics- 10/5 kA
  • Versions - 2P, 3P & 4Pwsn
  • Fixed Thermal & Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 4 Pole from 160 A - 200 A, 16 kA

With Adjustable Thermal & Fixed Magnetic Settings having 16 kA Breaking Capacity with Ics = 100% of Icu    IHLASF0160

  • Range 25 A - 250 A, Icu/Ics- 16/16 kA, 25/18.75 kA & 35/25 kA
  • Version - 1P, 3P & 4Pwsn
  • Adjustable Thermal & Fixed Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 4 Pole from 160 A - 250 A, 25 kA

With Adjustable Thermal & Fixed Magnetic Settings having 25 kA Breaking Capacity with Ics = 75% of Icu    IHLANF0160

  • Range 25 A - 250 A, Icu/Ics- 16/16 kA, 25/18.75 kA & 35/25 kA
  • Version - 1P, 3P & 4Pwsn
  • Adjustable Thermal & Fixed Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 4 Pole from 250 A - 630 A, 36 kA

With Adjustable Thermal & Fixed Magnetic Settings having 36 kA Breaking Capacity with Ics = 100% of Icu    IHLLSEBF0250

  • Range 250 A - 630 A, Icu/Ics- 36/36 kA & 50/37.5 kA
  • Versions - 3P & 4Pwsn
  • Adjustable Thermal & Fixed/Adjustable Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 4 Pole from 250 A - 630 A, 50 kA

With Adjustable Thermal & Fixed Magnetic Settings having 50 kA Breaking Capacity with Ics = 75% of Icu    IHLLNFBF0250

  • Range 250 A - 630 A, Icu/Ics- 36/36 kA & 50/37.5 kA
  • Versions - 3P & 4Pwsn
  • Adjustable Thermal & Fixed/Adjustable Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 4 Pole from 25 A - 125 A, 25 kA

With Adjustable Thermal & Fixed Magnetic Settings having 25 kA Breaking Capacity with Ics = 75% of Icu    IHLASF0025

  • Range 25 A - 250 A, Icu/Ics- 16/16 kA, 25/18.75 kA & 35/25 kA
  • Version - 1P, 3P & 4Pwsn
  • Adjustable Thermal & Fixed Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 4 Pole from 25 A - 125 A; 35 kA

With Adjustable Thermal & Fixed Magnetic Settings having 35 kA Breaking Capacity with Ics = 75% of Icu    IHLANF0025

  • Range 25 A - 250 A, Icu/Ics- 16/16 kA, 25/18.75 kA & 35/25 kA
  • Version - 1P, 3P & 4Pwsn
  • Adjustable Thermal & Fixed Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 4 Pole from 25 A - 160 A, 10 kA

With Fixed Thermal/Magnetic Settings having 10 kA Breaking Capacity with Ics = 100% of Icu    IHLGSF0025

  • Range 15 A - 100 A, Icu/Ics- 10/10 kA, 18/18 kA & 25/18.75 kA
  • Versions - 1P, 3P & 4Pwsn
  • Fixed Thermal & Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 4 Pole from 25 A - 160 A, 18 kA

With Fixed Thermal/Magnetic Settings having 18 kA Breaking Capacity with Ics = 100% of Icu    IHLGNF0025

  • Range 15 A - 100A, Icu/Ics- 10/10 kA, 18/18 kA & 25/18.75 kA
  • Versions - 1P, 3P & 4Pwsn
  • Fixed Thermal & Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 4 Pole from 25 A - 160 A, 25 kA

With Fixed Thermal/Magnetic Settings having 25 kA Breaking Capacity with Ics = 75% of Icu    IHLGHF0025

  • Range 15 A - 100 A, Icu/Ics- 10/10 kA, 18/18 kA & 25/18.75 kA
  • Versions - 1P, 3P & 4Pwsn
  • Fixed Thermal & Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 4 Pole from 25 A - 250 A, 35 kA

With Fixed Thermal/Magnetic Settings having 35 kA Breaking Capacity with Ics = 100% of Icu    IHLFNF0025

  • Range 25 A - 250 A, Icu/Ics- 35/35 kA & 50/50 kA
  • Versions - 1P, 3P & 4Pwsn
  • Fixed Thermal & Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 4 Pole from 25 A - 250 A, 50 kA

With Fixed Thermal/Magnetic Settings having 50 kA Breaking Capacity with Ics = 100% of Icu    IHLFHF0025

  • Range 25 A - 250 A, Icu/Ics- 35/35 kA & 50/50 kA
  • Versions - 1P, 3P & 4Pwsn
  • Fixed Thermal & Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 4 Pole from 40 A - 160 A, 27 kA

With Adjustable Thermal & Fixed Magnetic Settings having 27 kA Breaking Capacity with Ics = 100% of Icu    IHLNSDBF0040

  • Range 40 A - 160 A, Icu/Ics- 27/27 kA & 36/36 kA
  • Version - 1P, 2P, 3P & 4P
  • Adjustable Thermal & Fixed Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 4 Pole from 40 A - 160 A, 36 kA

With Adjustable Thermal & Fixed Magnetic Settings having 36 kA Breaking Capacity with Ics = 100% of Icu    IHLNHEBF0040

  • Range 40 A - 160 A, Icu/Ics- 27/27 kA & 36/36 kA
  • Version - 1P, 2P, 3P & 4P
  • Adjustable Thermal & Fixed Magnetic Settings

MRP Rs.: ₹

Download
Havells
Havells - Thermal Magnetic MCCB with 4 Pole from 15 A - 100 A

With Fixed Thermal/Magnetic Settings having 10kA Breaking capacity with Ics = 50% of Icu    IHLSHAAF0015

  • Range 15 A - 100 A, Icu/Ics- 10/5 kA
  • Versions - 2P, 3P & 4Pwsn
  • Fixed Thermal & Magnetic Settings

MRP Rs.: ₹ 0