Thermal Magnetic MCCB with 4 Pole from 40 A - 160 A, 27 kA

With Adjustable Thermal & Fixed Magnetic Settings having 27 kA Breaking Capacity with Ics = 100% of Icu

Range 40 A - 160 A, Icu/Ics- 27/27 kA & 36/36 kA

Different Current Ratings provide selection option depending on varied load conditions.

Version - 1P, 2P, 3P & 4P

Offered in different pole configurations based on system requirement.

Adjustable Thermal & Fixed Magnetic Settings

Overload Setting is Adjustable (70-100)% and Short Circuit Setting is minimum 10 times of Rated Current.

MRP Rs.: ₹ ..000

Buy Now
Integrated Earth Leakage Module Available

Integrated Earth Leakage Module Available

Provides protection against the Earth Fault and also lends compactness by virtue of inbuilt module.

Compact Size & Double Insulation

Compact Size & Double Insulation

Space saving in the Panel and has the conductive path insulated with double shield i.e. Cover & Facia

Suitable for Switch Disconnector Purpose

Suitable for Switch Disconnector Purpose

Circuit Breaker can be used as an Isolator.

Neutral Pole is protected and Fully Rated

Neutral Pole is protected and Fully Rated

Provision for addressing Residual Current in the Circuit.

Wide range of accessories available including Din Rail Mounting and Motorised Switching Mechanism

Wide range of accessories available including Din Rail Mounting and Motorised Switching Mechanism

Allows precise monitoring & control of circuit with the help of varied Internal & External Accessories

Provision of Push to trip button

Provision of Push to trip button

It is an alternate means to Trip the Breaker and also helps in checking the health of the Breaker.

Uniform front Escutcheon plate

Uniform front Escutcheon plate

Common Door Cut-out Facility provided lending Uniformity

Positive dolly position indication

Positive dolly position indication

Depicts the ON/OFF status of the breaker

Suitable for DC application

Suitable for DC application

Offers choice of system usage

Technical Specification

basic features
standard conformity IS / IEC 60947-2
rated operational voltage 415 V AC (1P @ 240 V AC)
rated insulation voltage 750 V AC
type of release Thermomagnetic
utilisation category A
rated frequency 50/60 Hz
ambient temp 400 °C (500 °C on request)
operating altitude 2000 m
humidity 0 - 90%
rated impulse voltage 8 kV
rating range 40A - 160A
type of release Thermal Adjustable and Magnetic Fixed Type
no. of poles Four
breaking capacity Icu = 27 kA, Ics = 100% of Icu

Demo Videos

HAVELLS SUPPORT

Customer Services
1800 11 0303,
1800 103 1313
Email-id
customercare[at]havells.com