Intelligent Power Factor controller IPFC CS 1003

8 and 12 steps

Recall function of recorded values

Key pad for user interface

Available in 8, 12, 14 stages

MRP Rs.: ₹ 0..000

Buy Now
User friendly program for target power factor, on/off delay, CT ratio

User friendly program for target power factor, on/off delay, CT ratio

Seven segment LCD display with backlight for readability in poorly illuminated areas

Seven segment LCD display with backlight for readability in poorly illuminated areas

Display parameters – kW, pF, kvar, kVA, V, A, Frequency

Display parameters – kW, pF, kvar, kVA, V, A, Frequency

Compatible with RS 232 (Galvanically isolated)

Compatible with RS 232 (Galvanically isolated)

User configurable parameters -  Target PF Setting, Power Factor Tolerance, CT ratio, total capacitor banks, under current, Over / Under frequency, Over / Under voltage threshold for alarm / tripping capacitor bank, time delay between steps (2 sec - 1800 sec.).

User configurable parameters - Target PF Setting, Power Factor Tolerance, CT ratio, total capacitor banks, under current, Over / Under frequency, Over / Under voltage threshold for alarm / tripping capacitor bank, time delay between steps (2 sec - 1800 sec.).

Download Parameters -  Target PF,  CT ratio, total capacitor banks, Capacitor banks status, under current, Over / Under voltage threshold for alarm / tripping capacitor bank, Over / Under frequency threshold for alarm / tripping capacitor bank, time delay between steps (2 seconds upto 1800 seconds)

Download Parameters - Target PF, CT ratio, total capacitor banks, Capacitor banks status, under current, Over / Under voltage threshold for alarm / tripping capacitor bank, Over / Under frequency threshold for alarm / tripping capacitor bank, time delay between steps (2 seconds upto 1800 seconds)

Load survey for 40 days for each 30 minutes interval consisting of: Active energy & demand, reactive energy & demand, apparent energy & demand, average power factor, voltage (average 30 minutes), date, time

Load survey for 40 days for each 30 minutes interval consisting of: Active energy & demand, reactive energy & demand, apparent energy & demand, average power factor, voltage (average 30 minutes), date, time

P.C. based software for data storing and system monitoring

P.C. based software for data storing and system monitoring

Technical Specification