Intelligent Power Factor controller IPFC CS 1001

8 and 12 steps

Recall function of recorded values

Key pad for user interface

Available in 8, 12, 14 stages

Imported by:

Country of Origin:

MRP Rs.: ₹ 10425.00 (incl. of all taxes)

Buy Now
User friendly program for target power factor, on/off delay, CT ratio

User friendly program for target power factor, on/off delay, CT ratio

Seven segment LCD display with backlight for readability in poorly illuminated areas

Seven segment LCD display with backlight for readability in poorly illuminated areas

Display parameters – kW, pF, kvar, kVA, V, A, Frequency

Display parameters – kW, pF, kvar, kVA, V, A, Frequency

Compatible with RS 232 (Galvanically isolated)

Compatible with RS 232 (Galvanically isolated)

User configurable parameters -  Target pF Setting, Power Factor Tolerance, CT ratio, total capacitor banks, under current, Over / Under frequency, Over / Under voltage threshold for alarm / tripping capacitor bank, time delay between steps (2 seconds - 1800 seconds).

User configurable parameters - Target pF Setting, Power Factor Tolerance, CT ratio, total capacitor banks, under current, Over / Under frequency, Over / Under voltage threshold for alarm / tripping capacitor bank, time delay between steps (2 seconds - 1800 seconds).

Download Parameters -  Target pF,  CT ratio, total capacitor banks, Capacitor banks status, under current, Over / Under voltage threshold for alarm / tripping capacitor bank, Over / Under frequency threshold for alarm / tripping capacitor bank, time delay between steps (2 seconds upto 1800 seconds)

Download Parameters - Target pF, CT ratio, total capacitor banks, Capacitor banks status, under current, Over / Under voltage threshold for alarm / tripping capacitor bank, Over / Under frequency threshold for alarm / tripping capacitor bank, time delay between steps (2 seconds upto 1800 seconds)

Load survey for 40 days for each 30 minutes interval consisting of: Active energy & demand, reactive energy & demand, apparent energy & demand, average power factor, voltage (average 30 minutes), date, time

Load survey for 40 days for each 30 minutes interval consisting of: Active energy & demand, reactive energy & demand, apparent energy & demand, average power factor, voltage (average 30 minutes), date, time

P.C. based software for data storing and system monitoring

P.C. based software for data storing and system monitoring

Technical Specification

Demo Videos

HAVELLS SUPPORT

Customer Care No.
08045 77 1313
Email-id
customercare@havells.com
 
Havells Consumer Connect
Download
Service Request Via SMS: Pincode <space> nature of complaint to 9212110303